CLEANING
THE NOZZLE or FILTER
- ALWAYS
DEPRESSURIZE CANISTER BEFORE REMOVING ANY PARTS.
- Remove
Nozzle from Nozzle Body leaving Nozzle Body in Brush.
- Rinse
both Nozzle and Filter with cleaner.
- Make
sure the Nozzle orifice and the Filter are clean and clear
of all dirt before putting it back together.
- Put
Nozzle and Filter in and reassemble. Tighten.
- If
Nozzle still does not spray correctly it may need to be
replaced.
PROBLEM:
TRIGGER WILL NOT SHUT OFF QUICKLY
Reason/Solution
| A)
|
The Filter is clogged. (if the filter is clogged it will not allow
the pressure to escape rapidly, thus resulting in a
lingering effect, with the air pressure taking an extended
time to dissipate, causing the product to continue to
spray, even after the trigger is released.) Clean
and replace. |
| B)
|
The Nozzle may be partially blocked. Clean and replace. |
PROBLEM:
APPLICATOR WILL NOT SPRAY AT ALL
Reason/Solution
| A)
|
Canister is completely full of liquid. Only
fill sprayer 2/3 full (32 ounces). |
| B)
|
No air pressure. Pressurize. |
| C)
|
Nozzle completely clogged. Clean or replace nozzle.
(See Cleaning the Nozzle above) |
PROBLEM:
PIN STREAM ONLY
Reason/Solution
| A)
|
Liquid too thick. Thin until sprayable. Consult
your liquid supplier for correct thinning procedures.
|
| B)
|
Too little air pressure. Must have a minimum of 40 psi. |
PROBLEM: FILLER CAP WON'T ACCEPT AIR
Reason/Solution
| A)
|
Dirty or damaged filler cap. Replace. |
| B)
|
#121 valve core is swollen. Replace. |
PROBLEM: LEAKS FROM TOP OF FILLER CAP
Reason/Solution
| A)
|
Filler cap has been damaged. Replace. |
| B)
|
#121 is loose. Tighten. |
| C)
|
#121 is worn. Replace. |
PROBLEM: LEAKS FROM BOTTOM OF FILLER CAP
Reason/Solution
| A)
|
#120 gasket is missing or dirty. Replace. |
PROBLEM:
LEAKS FROM NOZZLE
Reason/Solution
| A)
|
Dirty or worn Trigger Valve. Clean or replace
#550 or use #240 rebuild kit. |
|